That’s really the best part of this job. Ensure that corrosion prevention is discussed at the design/construction kick-off meeting and implemented on the plans at each submittal stage. Review and coordinate projects by a committee of public works design and maintenance, safety, environmental, and security to ensure projects are fully coordinated before work begins. Ensure that POL storage and distribution systems as-built drawings are included in the e-OMSI package [UFGS 01 78 24.00 20 ] at facility turnover from the Construction Agent. UFGS 09 90 00 Paints and Coatings covers the requirements for painting new and existing interior and exterior substrates, and other miscellaneous materials. In paragraph 3-5, Specification Requirements, UFC 1-200-01 (2018) DoD Building Code (General Building Requirements), requires the use of UFGS in accordance with UFC 1-300-02. By Capt. Disclaimer, Corrosion Prevention & Control (CPC) Source, Non-Government Standards (Limited Access), Tri-Services Building Technology Vendor Portal, Environmental Severity Classification (ESC), ISO Corrosivity Category Estimation Tool (ICCET) Toolbox, "Data About The Underground Storage Tank (UST) Program", Engineering and Construction Bulletins (ECB), D, CPO Recommended Facilities Corrosion Training Summary, "Bio-Deterioration of Materials in Biofuels", UFGS 09 97 13.15 Low VOC Polysulfide Interior Coating of Welded Steel Petroleum Fuel Tanks, UFGS 09 97 13.17 Three Coat Epoxy Interior Coating of Welded Steel Petroleum Fuel Tanks, UFGS 09 97 13.27 Exterior Coating of Steel Structures, UFGS 09 97 13.28 Protection of Buried Steel Piping and Steel Bulkhead Tie Rods, UFGS 09 97 23.13 Interior Lining for Concrete Storage Tanks (For Petroleum Fuels), UFGS 21 13 21.00 20 Foam Fire Extinguishing for Fuel Tank Protection, UFGS 26 42 13.00 20 Cathodic Protection by Galvanic Anodes, UFGS 26 42 14.00 10 Cathodic Protection System (Sacrificial Anode), UFGS 26 52 19.00 20 Cathodic Protection by Impressed Current, UFGS 33 08 55 Commissioning of Fuel Facility Systems, UFGS 33 11 23 Natural Gas and Liquid Petroleum Piping, UFGS 33 51 15 Natural-Gas / Liquid Petroleum Gas Distribution, UFGS 33 52 10 Fuel Systems Piping (Service Station), UFGS 33 52 43.11 Aviation Fuel Mechanical Equipment, UFGS 33 52 80 Liquid Fuels Pipeline Coating Systems, UFGS 33 56 10 Factory-Fabricated Fuel Storage Tanks, UFGS 33 58 00 Leak Detection for Fueling Systems, UFGS 33 61 13.19 Valves, Piping, and Equipment In Valve Manholes, UFGS 40 05 13 Pipelines, Liquid Process Piping, UFGS 41 65 10.00 10 [Diesel][Natural Gas] Fueled Engine Pump Drives. Industry Standards can also be found in the form of reference specifications. Installations in these locations spend considerable amount of resources addressing the corrosion in order to reduce the rate of corrosion damage. Note: We have 52 other definitions for POB in our Acronym Attic. James M. Beebe and Capt. External corrosion such as pitting and surface erosion can occur due to the external environment. These are easy points to earn but also easy points to lose.There will always be room to improve. The goal of 'Whole Building' Design is to create a successful high-performance building by applying an integrated design and team approach to the project during the planning and programming phases. Additionally, provide direction on what item to use based on other relative criteria such as soil corrosivity, ultraviolet exposure, solar radiation, biological, or other factors causing deterioration of a material or its properties because of a reaction of that material with its chemical environment." UFC 3-570-06 O&M: Cathodic Protections Systems provides guidance for inspection, operation, and maintenance of CP systems and should be used by field personnel to perform scheduled inspections and preventive maintenance, and to troubleshoot and repair defects. …and can cause significant damage to tanks and piping and environmental problems in very short periods of time." Record keeping is equally important. In preparation for the inspection, the 3rd CAB transitioned from the 1-gallon sampling method to Millipore sampling. Senator John Heinz (R-PA) for introducing a bill designed to exempt from combat one parent of military couples or single parents who were their children's sole provider. Common systems and structures requiring protective coatings and CP regardless of soil or water corrosivity include: For POL distribution pipelines the key parameters affecting internal pipe corrosion are: Facility SRM managers need to maintain in–house CP expertise to perform the day to day routine maintenance and inspection. UFC 3-570-01 Cathodic Protection provides policy and design requirements for CP systems which include fuels–related applications and associated qualification requirements for professionals providing design and engineering advice. CP is a specialized area of electrical technology so in-house electrical technicians need to be provided the resources to obtain and maintain their knowledge in CP. Capt. Suggest New. Even though ARMS occurs every other year, preparation happens daily.